Browsing Tag

Pediatrics

Advanced Technology Laboratory, General Information, Main lab

Update: COVID-19 Swab Supplies

If you are collecting COVID-19 swabs in your office or clinic, please order and collect using the saline swab kits (“liquid media” or “wet collection”) instead of the tube with no liquid media (“dry collection”).

• Liquid media swab kits will provide a faster turn-around time.

• Dry collection kits supplies are low.

Please refer to the COVID-19 PCR test in the Lab Catalog for the most up-to-date information on COVID-19 collection.

COVID-19 PCR Swab – LAB1230607

Continue Reading

Compliance & Safety, Education & Training, General Information

Self-Collected Swabs

Self-collected vaginal swabs may be used for testing as opposed to provider-collected swabs. Self-collected swabs are supported by current clinical guidelines as recent studies have shown their equivalence, if not superiority, in quality and their association with increased patient satisfaction.

NOTE: Self-collection must still take place in a healthcare setting and is not approved for at-home collection.

Continue Reading

General Information, Immunochemistry, Test Spotlight

New Insect Allergen Component Testing

Effective December 9, 2020, the following insect allergen components will be available:

Allergen Honey Bee Component Panel – EPIC #LAB1230747, Interface #1230747, CPT 86008

Allergen Common Wasp (Yellow Jacket) Component Panel – EPIC #LAB1230752, Interface #1230752, CPT 86008

Allergen Paper Wasp Component rPol d 5 – EPIC #LAB1230754, Interface #1230754, CPT 86008

Cross-reactive Carbohydrate Determinant (CCD) – EPIC #LAB1230755, Interface #1230755, CPT 86008 Continue Reading

Hemostasis/Coagulation

New Test: Thrombin Time

Effective March 4th, 2020, Thrombin Time will change from a sendout reference test performed by Mayo Clinic Laboratories to an in-house test performed by Spectrum Health Regional Laboratory. This test will be performed in the Coagulation Laboratory and will include a new reference range (please see link in Test Information below).

Thrombin Time is suitable for monitoring fibrinolysis therapy, screening for disorders of fibrin formation and in cases of suspected fibrinogen deficiency states. It is also useful for the differentiation between a heparin induced prolongation of the thrombin time and fibrin formation disorders.

For questions around this test, please contact the Coagulation Department at 616-267-2740.

TEST INFORMATION

Thrombin Time – Epic Code: #LAB11230581, Interface Code: #11230581, CPT: #85670

Education & Training, General Information, Test Utilization

Appropriate Thyroid Peroxidase Antibody Ordering

The most conclusive evidence for using thyroid peroxidase antibody (TPO) is predictive in nature when evaluating possible subclinical hypothyroidism. If this test is positive, hypothyroidism occurs at a rate of 4.3% per year versus 2.6% per year when the antibody is negative. While this scenario does not cover all clinical indications for ordering TPO, there is no definitive evidence that repeat TPO testing provides additional information.1

Based on this information the ordering of TPO within Spectrum Health is being modified. If the test is ordered more than once on a patient, a screen will appear in EPIC indicating the following: “This test should typically only be resulted once per lifetime. The duplicate checking indicates that this patient has already had this testing performed. Please see chart review for results.” This is not a “hard stop” but providers will need to click “Continue” to proceed with the order. Continue Reading

General Information, Immunochemistry

Immunochemistry Methodology Update

Effective December 11th, 2019, Spectrum Health Regional Laboratory’s Immunochemistry laboratory will be upgrading the following tests from the Immunoassay Vidas platform to the Multiplex flow immunoassay Bioplex 2200 platform.

Cytomegalovirus IgG Antibody

Cytomegalovirus IgM Antibody

Toxoplasma IgG Antibody

Toxoplasma IgM Antibody

Lyme Total Antibody

All tests will continue to have the same collection instructions, processing instructions, rejection criteria, specimen stability, turn-around-time, and qualitative reference ranges of negative. Continue Reading

General Information, Immunochemistry, Main lab, Test Utilization

Protein Electrophoresis Testing Update

In December, serum and urine protein electrophoresis testing will be simplified and standardized.  The only testing available will be:

Protein electrophoresis, serum, IFE if indicated 

Protein electrophoresis, random urine, do IFE if indicated 

Protein electrophoresis, 24 hour urine, do IFE if indicated 

In addition, on December 5, 2019, a new panel will be added which reflects expert recommendations for first line testing for monoclonal gammopathy, including plasma cell myeloma and most cases of amyloidosis, called “Monoclonal Gammopathy Screen

Protein electrophoresis, serum, IFE if indicated 

Kappa and lambda free light chains  Continue Reading