Test Update: Rubella IgG Antibody Testing

On January 24th, 2022 Rubella Antibody, IgG, Serum (LAB496) and Rubella IgG Antibody Quantitative (LAB3544) will be combined as LAB496 and moved to the Immunochemistry laboratory due to reagent constrains with the current vendor.

Testing will be available Monday-Friday with a turn-around-time of 1-3 days. Results will be reported qualitatively as Immune or Not Immune.  If quantitative results are needed, please fax Immunochemistry at 616-267-2771 or call 616-267-2770. Continue Reading

Molecular Diagnostics

Cystic Fibrosis (CF) Carrier Screen Discontinued

Effective February 1, 2022, the Cystic Fibrosis (CF) Carrier Screen test, which includes the 23 common variants for cystic fibrosis recommended by ACOG/ACMG, will be discontinued as an orderable test at Spectrum Health Laboratory.

The recommended replacement test is the Cystic Fibrosis Mutation Analysis (Test ID: CFP) offered by Mayo Clinic Laboratories, a 106-variant panel which includes the recommended 23 common variants.

Continue Reading

General Information, Hematology

Test Update: Cell Count with Differential, Body Fluid

Beginning Tuesday, January 4, 2022, Spectrum Health Laboratories will include an automated neutrophil (PMN) count on Cell Count with Differential, Body Fluid (LAB210) orders for peritoneal body fluids.   This component will be displayed in Epic as an absolute PMN count, body fluid.

• The absolute PMN count in the peritoneal fluid is calculated by multiplying the total nucleated cell count by the percentage of PMNs in the differential.

• This calculation aids in the diagnosis of spontaneous bacterial peritonitis (SBP).

• The diagnosis of bacterial peritonitis is established by a positive peritoneal fluid bacterial culture and an elevated peritoneal fluid absolute PMN count (≥250 cells/uL).

• Epic will automatically calculate the absolute PMN count in peritoneal body fluids based on the manual differential data.

• This component ONLY calculates for Cell Count with Differentials (LAB210) on PERITONEAL BODY FLUIDS Continue Reading

Chemistry, Immunochemistry, Main lab

Supply Update: Mono Kit Replacement

Spectrum Health and Spectrum Health Medical Group (SHMG) Supply Chain Update:

AbbottTM has discontinued their Mono Test Kit. The identified replacement product is from Cardinal HealthTM. This product is already in use in some spaces throughout Spectrum Health. Please see ITM number for the replacement product below and update your ordering processes accordingly.

Discontinued Product: ITM-1002651 Kit Test Mono CLIA Waived (Abbott 92407)

Replacement Product: ITM-1049839 Test Mono II Rapid (Cardinal Health CH1145) Continue Reading

Microbiology, Test Spotlight

Influenza Testing Recommendation Update (December 2021)

The mitigation strategies enacted during the COVID-19 pandemic to reduce the spread of this virus led to essentially non-existent influenza prevalence during the 2020-2021 winter season. However, influenza has now returned and case numbers are increasing throughout West Michigan.

Influenza prevalence guides the most appropriate testing approach and sufficient prevalence has now been reached for influenza rapid antigen testing (e.g. Sofia instrument) to have improved performance. The use of rapid antigen testing as a screening method during high prevalence reduces both the cost to the patient and turn-around-time as compared to lab-based molecular methods. Rapid antigen tests generally have high analytical specificity, but lack the sensitivity of nucleic acid amplification methods (e.g. PCR). For this reason, PCR testing is still recommended for hospitalized patients and for outpatients with a negative antigen result if influenza is still suspected and if the result will impact clinical decision making. Continue Reading

General Information, Hemostasis/Coagulation

Test Update: Prothrombin Time (Protime/PT)

Effective December 6, 2021, Spectrum Health Reference Laboratory (SHRL) Coagulation department will go live with a new lot of Prothrombin Time (Protime/PT) reagents. The reference range for the PT will be adjusted to reflect this reagent lot change and align with our Regional Laboratories. The new reference range will be 9.5 – 12.0 seconds. There will be no change to the INR ranges.

Test Current Reference Range New Reference Range
Prothrombin Time (PT) 9.7 – 12.6 seconds 9.5 – 12.0 seconds

Continue Reading

General Information

Sofia Strep Test Kit – Stable Supply

The supply of the Sofia Strep Test Kits (ITM-1052057) has returned to a stable level allowing the system to migrate back to this Strep Test kit solely. Please note once the remaining supply of the alternative strep test kit (Cardinal – ITM-1157857) is depleted, the item will be inactivated.

Due to this change, please ensure competencies are up to date for the Sofia Strep test kit.

Procedure Reference #17340, #24118.

 

Test Information:

Strep A Rapid, Throat Swab Only Epic Code [LAB8850]

Chemistry, General Information

Test Update: Thyroglobulin Antibody

Effective immediately, Thyroglobulin Antibody will be performed at Spectrum Health Reference Laboratory (SHRL, Grand Rapids, MI) and will no longer be a sendout to Mayo Clinical Laboratories. Collection instructions and other information may have changed, please visit the lab catalog for more information.

Thyroglobulin Tumor Marker will continue to be a sendout. If a Thyroglobulin Antibody is ordered with a Thyroglobulin Tumor Marker, then the Thyroglobulin Antibody will automatically be canceled as Mayo Clinic Laboratories will perform the Thyroglobulin Antibody as well as the Tumor Marker.

For questions and inquiries, please use the “Contact Us” link above.

 

TEST INFORMATION

New test: Thyroglobulin Antibody [LAB1230840] 

Former test: Thyroglobulin Antibody, Serum [LAB1230457]

Mentioned Test: Thyroglobulin, Tumor Marker, Serum [LAB864]

Advanced Technology Laboratory, General Information, Main lab, Test Utilization

Outpatient Respiratory Viral Testing

Spectrum Health Lab has noticed an increase in outpatient orders for Respiratory Pathogens by Film Array [LAB3359].  This may be due to a shortage of supplies for some Point of Care (POC) testing platforms.  Film Array is typically used for emergency and high acuity patients and therefore has a high cost that may not be covered by most patients’ insurance.  To lesson out of pocket costs for your patients, please order the below for RSV, COVID, or Flu testing. Continue Reading