PNH Flow Cytometry Test Results

High sensitivity flow cytometry testing for paroxysmal nocturnal hemoglobinuria (PNH) is a test done on patient’s peripheral blood to screen for the presence or absence of PNH clones and/or to follow PNH clonal populations.  The lower limit of detection of a PNH clone for the Spectrum Health laboratory has been validated as 0.01% (1:10,000) for red cells, 0.01% (1:10,000) for granulocytes and 0.1% for monocytes (1:1000).

The results from PNH flow cytometry testing can guide the clinical team in classifying a patient’s disease appropriately, analyzing the risk of disease progression, and choosing appropriate testing to monitor response to treatment. Therefore, the PNH flow cytometry test result will now include a pathologist’s interpretation based on the new recommendations given in Updated ICCS/ESCCA Consensus Guidelines for the Clinical Utility of Testing for GPI-Anchor Deficient Clones in Paroxysmal Nocturnal Hemoglobinuria (PNH) and other Bone Marrow Disorders (Accepted article by Dezern and Borowitz, doi: 10.1002/cyto.b.21608).